TES-6830+6801 Power and Harmonics Analyzer (100A)
TES-6830+6802 Power and Harmonics Analyzer (1000A)
TES-6830+3007 Power and Harmonics Analyzer ( 3000A)

TES-6800+3007
  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS Value(V 123 and L 123 )
  • Active Power(W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)
  • Energy (WH, KWH, KVARH, PFH)
  • Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
  • Display of 35 Parameters in One Screen(3P4W)
  • rogrammable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Average Demand (AD in W, KW, MW)
  • aximum Demand (MD in W, KW, MW) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in One Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples/Period)
  • Analysis of Total Harmonic Distortion (%THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%)
  • 3 Phase Voltage Unbalance Ratio (VUR)
  • 3 Phase Voltage Unbalance Factor (d0%, d2%)
  • Calculated Unbalance Current through Neutral Line (In)
  • Optical isolated USB Interface
  • Built-in Timer and Calendar for Data Logging
  • onductor Size: -Model 6801 30mm(approx) -Model 6802 5
  • 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
 
* Please refer to users manual for more detailed and up-to-date description of specification
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
Range
Resolution
Accuracy of Readings

6800+6801

6800+6802

6800+3007
5.0 – 999.9W
0.1W
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
1.000 – 9.999 KW
0.001 KW
±1% ± 8 dgts
±1% ± 8 dgts
±1% of VA Range ±8dgts
10.00 – 99.99 KW
0.01 KW
±1% ± 8 dgts
±1% ± 8 dgts
±1% of VA Range ±8dgts
100.0 – 999.9 KW
0.1 KW
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
1000 – 9999 KW
1 KW
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
0.000 – 9.999MW

0.001MW

±1% ± 8 dgts
±1% of VA Range ±8dgts
AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1) 
Range
Resolution
Accuracy of Readings

6800+6801

(Overload Protection AC200A)

0.050 – 9.999A
0.001A
±0.5% ± 5dgts
10.00 – 60.00A
0.01A
±0.5% ± 5dgts
60.00 – 99.99A
0.01A
±1.0% ± 5dgts

6800+6802

(Overload Protection AC2000A)

0.04 – 10.00A
0.01A
0.4A – 100.0A
0.1A
±0.5% ± 5dgts
4.0 – 1000.0A
1A
±0.5% ± 5dgts
6800+ 3007

(Overload Protection AC3500A)

4 – 300A
0.1A
±1% of Range ±5dgts
300.0 – 999.9A
0.1A
±1% of Range ±5dgts
1000 – 3000A
1A
±1% of Range ±5dgts
AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest FActor<4)
Range
Resolution
Accuracy of Readings
Range
Resolution
Accuracy of Readings

4.0V – 500.0 (Phase to Neutral)

0.1V

± 0.5% ± 5dgts

4.0V –600.0V (Phase to phase)

0.1V

± 0.5% ± 5dgts

Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)
Range
In Percentage
In Magnitude
Resolution
Accuracy of readings
Resolution
Accuracy of readings
1 – 20 th

0.1%

±2%

0.1 V

±2% ±0.5V
21 – 49 th
4% of reading ±2.0%
4% of reading ±0.5A
50 – 99 th
6% of reading ±2.0%
6% of reading ±0.5A

Harmonics of AC Current in % and in Magnitude

Model 6800+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

Range
In Percentage
In magnitude
Resolution
Accuracy of reading
Resolution
Accuracy of reading
1 – 10 th

0.1%

±0.2 of reading ±1%
0.1mA / 0.1A
±0.2% of reading ±7dgts
11 – 20 th
±2% of reading ±1%
±2% of reading ±7dgts
2 1 – 50 th (A range)
±5% of reading ±1%
±5% of reading ±7dgts
2 1 – 50 th (mA range)
±10% of reading ±1%
±10% of reading ±7dgts
5 1 – 99 th
±35% of reading ±1%
±35% of reading ±7dgts
Model 6800+6802(1000A);6800+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)
Range
In Percentage
In Magnitude
Resolution
Accuracy of reading
Resolution
Accuracy of reading
1 – 20 th
0.1%
±2%

0.1A(6802) / 0.3A(3007)

±2% of reading ±0.4A/0.6A
21 – 49 th
4% of reading ±2.0%
±4% of reading ± 0.4A/0.6A
50 – 99 th
6% of reading ±2.0%
±6% of reading ± 0.4A/0.6A
Total Harmonic Distortion
Range
Resolution
Accuracy(6801)
Accuracy(6802)
Accuracy(3007)
0.0 – 20%
0.1%
±1%
±2%
±2%
20 – 100%
0.1%
±3% of reading ±5%
±6% of reading ±1%
±6% of Range ±1%
100 – 999.9%
0.1%
±10% of reading ±10%
±10% of reading ±1%

±10% of Range ±1%

Peak Value of Ac Voltage or AC Current ,VT=1
Range
Samping Time
Accuracy of reading
50Hz
39 μS
±5% ±30digits
60Hz
33 μS
±5% ±30 digits
Crest Factor (C.F.) of ACV or ACA ,VT=1
Range
Resolution
Accuracy of reading
1.00 – 99.99
0.01
±5% ±30digits
Frequency in AUTO mode
Range
Resolution
Accuracy of reading
45 – 65Hz
0.1Hz
0.1Hz
Power Factor (PF)
Range
Resolution
Accuracy of reading
0.00 – 1.00
0.01
± 0.04
Phase Angle (Φ)
Range
Resolution
Accuracy of reading
-180 。 to 180 。
0.1 。
± 1 。
 
Conductor Size (6801) 約30mm (approx)
Conductor Size (6802) 約55mm(approx.), 64 X 24mm(Bus Bar)
Battery Type 1.5V SUM-3 x 8
Display Dot Matrix LCD with backlight
Power Consumption 140mA (approx.)
External DC Input DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)
LCD update rate 1 times / sec
No. Of Samples/Period 1024
Operating Humidity < 85% relative
Operating Temperature -10°C to 50°C
Storage Humidity < 75% relative
Storage Temperature - 20°C to 60°C
Weight(6800) 1160g
Weight(6801) 200g
Weight(6802) 600g
Dimension(6800) 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)
Dimension(6801) 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)
TES- 1370 NDIR CO 2 METER

  • CO 2 : 0 ~ 6,000 ppm range, Diffusion sampling mode.
  • Three LCD Display for CO 2 , %RH Humidity and Air Temperature.
  • Maintenance free dual wavelength NDIR infrared CO 2 sensor (non-dispersive infrared).
  • Continuous or manual data logging (20,000 sets).
  • Data hold & Maximum / Minimum with Time stamp.
  • Data Memory and READ function.
  • Alarm and Time setting.
  • RS-232 function / Software.
  • Backlight display function.
  • Simple and safe to use.
 
Measuring Range

CO 2 : 0~ 6,000 ppm
Temperature : -20℃ ~ 60℃ (-4℉ ~ 140℉)
Humidity : 10%RH ~ 95%RH

Resolution

CO 2 :1ppm
0.1℃ / 0.1℉ / 0.1%RH

Accuracy

CO 2 : ±3% of reading or ±50ppm, which is greater.
Temperature : ±0.5℃, ±0.9℉
Humidity : ±3%RH ( at 25℃, 30 ~ 95% RH ).
±5%RH ( at 25℃, 10 ~ 30% RH )

Manual Data Memory Capacity 99 sets (Direct reading from LCD display)
Auto Memory Capacity Approx. 20,000 sets
Operating Conditions 5℃ ~ 50℃ (41℉ ~ 122℉)
10 ~ 90% R.H.
Power Source 6pcs size AAA Alkaline Battery (large current) batteries.
Battery Life Approx. 8 hours by using alkaline (large current)
batteries (without backlight or Alarm function).
For long time datalogging, please use AC adapter.
Size 158(L) ×72(W) ×35(H)mm
Weight Approx. 255g (including batteries)
Accessories Instruction Manual, Battery, AC Adaptor (110Vor220V),
Software CD Rom, RS232 Cable & Carrying case.
TES-52 Sound Level Meter

  • 0.1dB Resolution
  • Range from 30 to 130dB
  • A&C frequency weighting
  • Fast/Slow Dynamic characteristic
  • Maximum with Elapsed time
  • Manual data memory and read
  • 5Selectable Ranges
  • Bargraph Indication
  • Logging Function (99 Sets)
 
Applicable standards IEC Pub 60651 Type2 , ANSI S1.4 Type 2
Digital display 4 digital LCD,0.1 dB resolution ,updated every 0.5s
Measurement Level 30dB to 130dB
Measurement Frequency range 31.5 Hz to 8KHz
Frequency Weighting A and C
Time weight Fast and Slow
Microphone 1/2 inch Electret condenser microphone
Measureement level range 5 ranges in 10-dB step : 30~90dB , 40~100dB

50~110dB , 60~120dB

70~130dB

Quasi-analog bar indicator 1-dB steps, 60dB display range, updated every 0.125s
Display Warning function
Overrange indicator
Underrange indicator
Displayed at the upper limit
Displayed at the lower limit
Manual data memory capacity 99 sets
Analong AC / DC output 2Vrms ( at full scale ) , 10mVDC / dB
Power supply Four 1.5V LR-6/AA size alkaline cell, AC adapter
Battery Life about 50 hours
Operating temperature , humidity 0 ℃ ~ 50 ℃ (32 ℉ ~122 ℉ )R.H.<80% non-condensing

-10 ℃ ~60 ℃ (14 ℉ ~140 ℉ )R.H<70% non-condensing

Dimensions 258 (L)×68(W)×27(H)mm
Weight Approx. 310g
Accessories Instruction manual , Battery ,
Adjustment screwdriver , Wind shield
TES-1339 Light Meter Pro.

  • Dual Display, 4-digit LCD reading.
  • Spectral Sensitivity close to CIE photopic Curve.
  • Measuring Levels Ranging 0.01 to 999900 Lux,0.01 to 99990 fc, Autoranging 5 step.
  • Accurate and Instant response.
  • Integral illuminance measurement.
  • Luminous intensity measurement.
  • Data Hold function.
  • Data memory and read function.
  • Reference value setting for relative or percentage deviation measurement.
  • Ripple measurement for STRAY + LIGHT function.
  • Time-hold function.
  • Point - average function.
  • Comparator function.
  • Auto power off function.
  • CNS 5119 Class Ⅱ .
 
Display Dual display 4 digit LCD read out.
Measuring Range 99.99, 999.9, 9999, 99990, 999900 Lux
9.999, 99.99, 999.9, 9999, 99990 fc
Auto rangeing (5 step) (1 fc = 10.76 Lux)
Overrange Display OL is displayed
Resolution 0.01 Lux, 0.001 fc
Accuracy ± 3% rdg ± 5dgt (Calibrated to standard
incandescent lamp, 2856° Κ )
CIE photopic f ' 1 ≦ 6 %
Temperature Characteristics

± 0.1%/ ℃

Measuring Rate Approximately 5 time/sec
Photosensor Silicon photodiodes
Data Memory Capacity 50 sets. (Direct reading from LCD display)
Operating / Storage Conditions 0 ℃ ~ 50 ℃ <80% RH
-10 ℃ ~ 60 ℃ <70%RH
Power Source 6 pcs AAA size Battery

Battery Life (typical)

100 hours
Photosensor Lead Length 150 cm (approx.)
Photosensor Dimensions 100(L) × 60(W) × 27(H)mm
Dimension 150(L) × 72(W) × 33(H)mm
Weight 250g
Accessories Carrying case, Instruction manual, Battery
TES-1326S/1327/1237K Infrared Thermometer

----TES-1327K----
  • 0.1 ℃/0.2 ℉ Resolution
  • -20 ℃ ~ 500℃
  • Built-in Laser Sighting/Backlight LCD display
  • Memory / Read logging Capacity (50 Sets) (1327)
  • Adjustable emissivity (1327)
  • Audible and visible alarm (1327/1237K)
  • MAX / MIN Reading
  • Data memory and read function (1327/1237K)
  • Emissivity adjustable (1327/1237K)

 

 
INFRARED THERMOMETER :
Display Backlight LCD display
Measurement Range -35 ℃ ~ 500℃ (-4 ℉ ~ 932 ℉ )
Resolution 0.1 ℃ / 0.2 ℉
Accuracy ± 2% reading or ± 2 ℃
Spectral Response 6 ~ 14μm
Field of View 10 :1 optics ratio with a 1” min target
Emissivity 0.17~1.00(1326:fixed 0.95)
Sighting Laser marker < 1mw
K-TYPE THERMOMETER(for 1327K):
Measurement Range -150 ℃~1350℃(-238 ℉~1999℉)
Resolution 0.1 ℃ / 1℃ , 0.1℉ / 1℉

 

Function
Resloution
Range
Accuracy
0.1 ℃
-150 ℃~0℃
±(0.2%rdg+1.0 ℃)
0 ℃~200℃
±(0.1%rdg+1.0 ℃ )
1 ℃
200 ℃~1350℃
±(0.2%rdg+2 ℃)
0.1 ℉
-238 ℉~32℉
±(0.2%rdg+2 ℉)
32 ℉~200℉
±(0.1%rdg+2 ℉)
1 ℉
200 ℉~1999℉
±(0.2%rdg+4 ℉)

GENERAL SPECIFICATIONS:

Data memory capacity 50 sets (Direct reading from LCD display)(1327/1327K)
Auto power off approx. 15 sec
Battery Life Approx. 100 hours (laser pointer and backlight aren't on use) (Alkaline)
Power Source One 9V cell( ANSI/NEDA-1604A,IEC-6LR61)
Operating / Storage Conditioon 0 ℃~50℃ (32 ℉~122℉)below 80%RH -10℃~60℃(14℉~140℉)below 7%RH
Dimensions 172mm*118mm*46mm
Weight 220g
Accessories Instruction manual ,Battery
TES-3600 3P4W POWER ANALYZER

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (512KB Memory, 20,000 sets)
  • Programmable Trigger - Points and Start / Stop Time.
  • RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.
 
Voltage Measurement (V)
Ranges

Method

Accuracy
Input impedance
600.0V
True RMS
± 0.5%rdg ± 10dgts (>30V)
2M Ω
Current Measurement (A)
Ranges
Method
Accuracy
250A 、 500A 、 1000A

True RMS

± 0.5%rdg ± 10dgts+clamp on sensor specifications

Active Power Measurement (KW)
Ranges

Accuracy

Effect of power factor
600.0KW
± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)
Ranges
Accuracy
Effect of power factor
600.0KVAR
± 0.5%rdg ± 10dgts+clamp on sensor specifications
± 0.1%rdg
Apparent Power Measurement (KVA)
Ranges
Accuracy
600.0KVA
± 0.5%rdg ± 10dgts+clamp on sensor specifications
Power Integration Measurement
Power Integration
Resolution
Accuracy