Test & Measurement Instruments 
TES-6830+6801 Power and Harmonics Analyzer (100A)
TES-6830+6802 Power and Harmonics Analyzer (1000A)
TES-6830+3007 Power and Harmonics Analyzer ( 3000A)

TES-6800+3007
  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS Value(V 123 and L 123 )
  • Active Power(W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)
  • Energy (WH, KWH, KVARH, PFH)
  • Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
  • Display of 35 Parameters in One Screen(3P4W)
  • rogrammable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Average Demand (AD in W, KW, MW)
  • aximum Demand (MD in W, KW, MW) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in One Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples/Period)
  • Analysis of Total Harmonic Distortion (%THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%)
  • 3 Phase Voltage Unbalance Ratio (VUR)
  • 3 Phase Voltage Unbalance Factor (d0%, d2%)
  • Calculated Unbalance Current through Neutral Line (In)
  • Optical isolated USB Interface
  • Built-in Timer and Calendar for Data Logging
  • onductor Size: -Model 6801 30mm(approx) -Model 6802 5
  • 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
 
* Please refer to users manual for more detailed and up-to-date description of specification
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
Range
Resolution
Accuracy of Readings

6800+6801

6800+6802

6800+3007
5.0 – 999.9W
0.1W
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
1.000 – 9.999 KW
0.001 KW
±1% ± 8 dgts
±1% ± 8 dgts
±1% of VA Range ±8dgts
10.00 – 99.99 KW
0.01 KW
±1% ± 8 dgts
±1% ± 8 dgts
±1% of VA Range ±8dgts
100.0 – 999.9 KW
0.1 KW
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
1000 – 9999 KW
1 KW
±1% ± 8dgts
±1% ± 8dgts
±1% of VA Range ±8dgts
0.000 – 9.999MW

0.001MW

±1% ± 8 dgts
±1% of VA Range ±8dgts
AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1) 
Range
Resolution
Accuracy of Readings

6800+6801

(Overload Protection AC200A)

0.050 – 9.999A
0.001A
±0.5% ± 5dgts
10.00 – 60.00A
0.01A
±0.5% ± 5dgts
60.00 – 99.99A
0.01A
±1.0% ± 5dgts

6800+6802

(Overload Protection AC2000A)

0.04 – 10.00A
0.01A
0.4A – 100.0A
0.1A
±0.5% ± 5dgts
4.0 – 1000.0A
1A
±0.5% ± 5dgts
6800+ 3007

(Overload Protection AC3500A)

4 – 300A
0.1A
±1% of Range ±5dgts
300.0 – 999.9A
0.1A
±1% of Range ±5dgts
1000 – 3000A
1A
±1% of Range ±5dgts
AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest FActor<4)
Range
Resolution
Accuracy of Readings
Range
Resolution
Accuracy of Readings

4.0V – 500.0 (Phase to Neutral)

0.1V

± 0.5% ± 5dgts

4.0V –600.0V (Phase to phase)

0.1V

± 0.5% ± 5dgts

Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)
Range
In Percentage
In Magnitude
Resolution
Accuracy of readings
Resolution
Accuracy of readings
1 – 20 th

0.1%

±2%

0.1 V

±2% ±0.5V
21 – 49 th
4% of reading ±2.0%
4% of reading ±0.5A
50 – 99 th
6% of reading ±2.0%
6% of reading ±0.5A

Harmonics of AC Current in % and in Magnitude

Model 6800+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

Range
In Percentage
In magnitude
Resolution
Accuracy of reading
Resolution
Accuracy of reading
1 – 10 th

0.1%

±0.2 of reading ±1%
0.1mA / 0.1A
±0.2% of reading ±7dgts
11 – 20 th
±2% of reading ±1%
±2% of reading ±7dgts
2 1 – 50 th (A range)
±5% of reading ±1%
±5% of reading ±7dgts
2 1 – 50 th (mA range)
±10% of reading ±1%
±10% of reading ±7dgts
5 1 – 99 th
±35% of reading ±1%
±35% of reading ±7dgts
Model 6800+6802(1000A);6800+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)
Range
In Percentage
In Magnitude
Resolution
Accuracy of reading
Resolution
Accuracy of reading
1 – 20 th
0.1%
±2%

0.1A(6802) / 0.3A(3007)

±2% of reading ±0.4A/0.6A
21 – 49 th
4% of reading ±2.0%
±4% of reading ± 0.4A/0.6A
50 – 99 th
6% of reading ±2.0%
±6% of reading ± 0.4A/0.6A
Total Harmonic Distortion
Range
Resolution
Accuracy(6801)
Accuracy(6802)
Accuracy(3007)
0.0 – 20%
0.1%
±1%
±2%
±2%
20 – 100%
0.1%
±3% of reading ±5%
±6% of reading ±1%
±6% of Range ±1%
100 – 999.9%
0.1%
±10% of reading ±10%
±10% of reading ±1%

±10% of Range ±1%

Peak Value of Ac Voltage or AC Current ,VT=1
Range
Samping Time
Accuracy of reading
50Hz
39 μS
±5% ±30digits
60Hz
33 μS
±5% ±30 digits
Crest Factor (C.F.) of ACV or ACA ,VT=1
Range
Resolution
Accuracy of reading
1.00 – 99.99
0.01
±5% ±30digits
Frequency in AUTO mode
Range
Resolution
Accuracy of reading
45 – 65Hz
0.1Hz
0.1Hz
Power Factor (PF)
Range
Resolution
Accuracy of reading
0.00 – 1.00
0.01
± 0.04
Phase Angle (Φ)
Range
Resolution
Accuracy of reading
-180 。 to 180 。
0.1 。
± 1 。
 
Conductor Size (6801) 約30mm (approx)
Conductor Size (6802) 約55mm(approx.), 64 X 24mm(Bus Bar)
Battery Type 1.5V SUM-3 x 8
Display Dot Matrix LCD with backlight
Power Consumption 140mA (approx.)
External DC Input DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)
LCD update rate 1 times / sec
No. Of Samples/Period 1024
Operating Humidity < 85% relative
Operating Temperature -10°C to 50°C
Storage Humidity < 75% relative
Storage Temperature - 20°C to 60°C
Weight(6800) 1160g
Weight(6801) 200g
Weight(6802) 600g
Dimension(6800) 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)
Dimension(6801) 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)
TES- 1370 NDIR CO 2 METER

  • CO 2 : 0 ~ 6,000 ppm range, Diffusion sampling mode.
  • Three LCD Display for CO 2 , %RH Humidity and Air Temperature.
  • Maintenance free dual wavelength NDIR infrared CO 2 sensor (non-dispersive infrared).
  • Continuous or manual data logging (20,000 sets).
  • Data hold & Maximum / Minimum with Time stamp.
  • Data Memory and READ function.
  • Alarm and Time setting.
  • RS-232 function / Software.
  • Backlight display function.
  • Simple and safe to use.
 
Measuring Range

CO 2 : 0~ 6,000 ppm
Temperature : -20℃ ~ 60℃ (-4℉ ~ 140℉)
Humidity : 10%RH ~ 95%RH

Resolution

CO 2 :1ppm
0.1℃ / 0.1℉ / 0.1%RH

Accuracy

CO 2 : ±3% of reading or ±50ppm, which is greater.
Temperature : ±0.5℃, ±0.9℉
Humidity : ±3%RH ( at 25℃, 30 ~ 95% RH ).
±5%RH ( at 25℃, 10 ~ 30% RH )

Manual Data Memory Capacity 99 sets (Direct reading from LCD display)
Auto Memory Capacity Approx. 20,000 sets
Operating Conditions 5℃ ~ 50℃ (41℉ ~ 122℉)
10 ~ 90% R.H.
Power Source 6pcs size AAA Alkaline Battery (large current) batteries.
Battery Life Approx. 8 hours by using alkaline (large current)
batteries (without backlight or Alarm function).
For long time datalogging, please use AC adapter.
Size 158(L) ×72(W) ×35(H)mm
Weight Approx. 255g (including batteries)
Accessories Instruction Manual, Battery, AC Adaptor (110Vor220V),
Software CD Rom, RS232 Cable & Carrying case.
TES-52 Sound Level Meter

  • 0.1dB Resolution
  • Range from 30 to 130dB
  • A&C frequency weighting
  • Fast/Slow Dynamic characteristic
  • Maximum with Elapsed time
  • Manual data memory and read
  • 5Selectable Ranges
  • Bargraph Indication
  • Logging Function (99 Sets)
 
Applicable standards IEC Pub 60651 Type2 , ANSI S1.4 Type 2
Digital display 4 digital LCD,0.1 dB resolution ,updated every 0.5s
Measurement Level 30dB to 130dB
Measurement Frequency range 31.5 Hz to 8KHz
Frequency Weighting A and C
Time weight Fast and Slow
Microphone 1/2 inch Electret condenser microphone
Measureement level range 5 ranges in 10-dB step : 30~90dB , 40~100dB

50~110dB , 60~120dB

70~130dB

Quasi-analog bar indicator 1-dB steps, 60dB display range, updated every 0.125s
Display Warning function
Overrange indicator
Underrange indicator
Displayed at the upper limit
Displayed at the lower limit
Manual data memory capacity 99 sets
Analong AC / DC output 2Vrms ( at full scale ) , 10mVDC / dB
Power supply Four 1.5V LR-6/AA size alkaline cell, AC adapter
Battery Life about 50 hours
Operating temperature , humidity 0 ℃ ~ 50 ℃ (32 ℉ ~122 ℉ )R.H.<80% non-condensing

-10 ℃ ~60 ℃ (14 ℉ ~140 ℉ )R.H<70% non-condensing

Dimensions 258 (L)×68(W)×27(H)mm
Weight Approx. 310g
Accessories Instruction manual , Battery ,
Adjustment screwdriver , Wind shield
TES-1339 Light Meter Pro.

  • Dual Display, 4-digit LCD reading.
  • Spectral Sensitivity close to CIE photopic Curve.
  • Measuring Levels Ranging 0.01 to 999900 Lux,0.01 to 99990 fc, Autoranging 5 step.
  • Accurate and Instant response.
  • Integral illuminance measurement.
  • Luminous intensity measurement.
  • Data Hold function.
  • Data memory and read function.
  • Reference value setting for relative or percentage deviation measurement.
  • Ripple measurement for STRAY + LIGHT function.
  • Time-hold function.
  • Point - average function.
  • Comparator function.
  • Auto power off function.
  • CNS 5119 Class Ⅱ .
 
Display Dual display 4 digit LCD read out.
Measuring Range 99.99, 999.9, 9999, 99990, 999900 Lux
9.999, 99.99, 999.9, 9999, 99990 fc
Auto rangeing (5 step) (1 fc = 10.76 Lux)
Overrange Display OL is displayed
Resolution 0.01 Lux, 0.001 fc
Accuracy ± 3% rdg ± 5dgt (Calibrated to standard
incandescent lamp, 2856° Κ )
CIE photopic f ' 1 ≦ 6 %
Temperature Characteristics

± 0.1%/ ℃

Measuring Rate Approximately 5 time/sec
Photosensor Silicon photodiodes
Data Memory Capacity 50 sets. (Direct reading from LCD display)
Operating / Storage Conditions 0 ℃ ~ 50 ℃ <80% RH
-10 ℃ ~ 60 ℃ <70%RH
Power Source 6 pcs AAA size Battery

Battery Life (typical)

100 hours
Photosensor Lead Length 150 cm (approx.)
Photosensor Dimensions 100(L) × 60(W) × 27(H)mm
Dimension 150(L) × 72(W) × 33(H)mm
Weight 250g
Accessories Carrying case, Instruction manual, Battery
TES-1326S/1327/1237K Infrared Thermometer

----TES-1327K----
  • 0.1 ℃/0.2 ℉ Resolution
  • -20 ℃ ~ 500℃
  • Built-in Laser Sighting/Backlight LCD display
  • Memory / Read logging Capacity (50 Sets) (1327)
  • Adjustable emissivity (1327)
  • Audible and visible alarm (1327/1237K)
  • MAX / MIN Reading
  • Data memory and read function (1327/1237K)
  • Emissivity adjustable (1327/1237K)

 

 
INFRARED THERMOMETER :
Display Backlight LCD display
Measurement Range -35 ℃ ~ 500℃ (-4 ℉ ~ 932 ℉ )
Resolution 0.1 ℃ / 0.2 ℉
Accuracy ± 2% reading or ± 2 ℃
Spectral Response 6 ~ 14μm
Field of View 10 :1 optics ratio with a 1” min target
Emissivity 0.17~1.00(1326:fixed 0.95)
Sighting Laser marker < 1mw
K-TYPE THERMOMETER(for 1327K):
Measurement Range -150 ℃~1350℃(-238 ℉~1999℉)
Resolution 0.1 ℃ / 1℃ , 0.1℉ / 1℉

 

Function
Resloution
Range
Accuracy
0.1 ℃
-150 ℃~0℃
±(0.2%rdg+1.0 ℃)
0 ℃~200℃
±(0.1%rdg+1.0 ℃ )
1 ℃
200 ℃~1350℃
±(0.2%rdg+2 ℃)
0.1 ℉
-238 ℉~32℉
±(0.2%rdg+2 ℉)
32 ℉~200℉
±(0.1%rdg+2 ℉)
1 ℉
200 ℉~1999℉
±(0.2%rdg+4 ℉)

GENERAL SPECIFICATIONS:

Data memory capacity 50 sets (Direct reading from LCD display)(1327/1327K)
Auto power off approx. 15 sec
Battery Life Approx. 100 hours (laser pointer and backlight aren't on use) (Alkaline)
Power Source One 9V cell( ANSI/NEDA-1604A,IEC-6LR61)
Operating / Storage Conditioon 0 ℃~50℃ (32 ℉~122℉)below 80%RH -10℃~60℃(14℉~140℉)below 7%RH
Dimensions 172mm*118mm*46mm
Weight 220g
Accessories Instruction manual ,Battery
TES-3600 3P4W POWER ANALYZER

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (512KB Memory, 20,000 sets)
  • Programmable Trigger - Points and Start / Stop Time.
  • RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.
 
Voltage Measurement (V)
Ranges

Method

Accuracy
Input impedance
600.0V
True RMS
± 0.5%rdg ± 10dgts (>30V)
2M Ω
Current Measurement (A)
Ranges
Method
Accuracy
250A 、 500A 、 1000A

True RMS

± 0.5%rdg ± 10dgts+clamp on sensor specifications

Active Power Measurement (KW)
Ranges

Accuracy

Effect of power factor
600.0KW
± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)
Ranges
Accuracy
Effect of power factor
600.0KVAR
± 0.5%rdg ± 10dgts+clamp on sensor specifications
± 0.1%rdg
Apparent Power Measurement (KVA)
Ranges
Accuracy
600.0KVA
± 0.5%rdg ± 10dgts+clamp on sensor specifications
Power Integration Measurement
Power Integration
Resolution
Accuracy
0.0KWh to 9999MWh
0.1KWh
± 0.5%rdg ± 10dgts+clamp on sensor specifications
0.0Kvarh to 9999Mvarh
0.1Kvarh
0.0KVAh to 9999MVAh
0.1KVAh
Power Factor Measurement
Ranges
Accuracy
Polarity display
-1.000(lead) to 0.000 to + 1.000 (lag)

± 1dgt for each calculation from measured values

When the current lags the voltage unsigned ; when the current leads the voltage : "-".
Frequency Measurement
Ranges
Measurement source
Accuracy
40Hz to 100Hz
Voltage U1
± 0.5%rdg ± 1dgt
General Specifications
Size 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
Operating Temperature and Humidity 0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing
Storage Temperature and Humidity - 10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing
Accessories

Instruction manual , Softwar CD rom / Optical RS-232 interface , Deluxe carrying case , Battery ( “AA” 1.5V ′ 8pcs ) , AC adaptor (110V  12V ; 220V  12V) , 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm) , 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)

TES-1351 Sound Level Meter

  • 0.1dB Resolution
  • Maximum hold function
  • AUX OUTPUT JACKS
 
Standard applied IEC 651 Type2
Range A LO (Low) - Weighting: 35- 90dB
A HI (High) - Weighting: 75-130dB
C LO (Low) - Weighting: 35- 90dB
C HI (High) - Weighting: 75-130dB
Resolution 0.1dB
Frequency Range 31.5Hz to 8KHz
Accuracy ± 1.5dB (ref 94dB @1KHz)
Dynamic Range 55dB
Frequency Weighting A、C
Time Weighting Slow & Fast
Maximum Hold Decay < 1dB/3min
Microphone Electret condenser microphone
Calibration Electrical calibration by using the internal oscillator
(1KHz sine Wave at 94dB)
Auxilitary Output AC conditioned, 0.55Vrms corresponding to
each range step, impedance: 600 W
DC conditioned, 10mV/dB (nominally)
impedance: 100 W
Operating Condition 0 ℃ to 40 ℃< 80% R. H.
Storage Condition -10 ℃ to 60 ℃< 70% R.H.
Display 4 digitals
Power Supply one 9V battery
Size 240mm(L)x68mm(W)x25mm(H)
Weight 215g
Accessorie Instruction Manual, 9V Battery, Carrying Case,
Screwdriver, Windscreen.

 

PROVA-5601/5637 Clamp-on Ground Resistance Tester

  • Non-Contact Ground Resistance Measurement
  • No Auxiliary Electrode Needed
  • Jaw Diameter Φ 23 mm (5601)
  • Jaw Diameter Φ 35 mm(5637)
  • 0.025 – 1500 Ohm
  • 0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS
  • 116 Sets of Memory(5601,5637)
  • Programmable Hi and Lo Alarm(5601,5637)
  • Programmable Data Logging (5601,5637)

  • Telecommunication
  • Cable TV system
  • Electrical Power Plant
  • Cellular Phone System
  • Factory and Facility
  • Gas Station Tank
 
Ground Resistance (Auto range)
Range
Resolution
Accuracy of Reading 1,2
0.025 - 0.250 Ω
0.002 Ω
± 1.5% ± 0.02 Ω
0.250 - 1.000 Ω
0.02 Ω
± 1.5% ± 0.02 Ω
1.001 - 9.999 Ω
0.02 Ω
± 1.5% ± 0.1 Ω
10.00 - 50.00 Ω
0.04 Ω
± 1.5% ± 0.1 Ω
50.01 - 99.99 Ω
0.04 Ω
± 1.5% ± 0.5 Ω
100.0 - 200.0 Ω
0.4 Ω
± 3.0% ± 1.0 Ω
200.1 - 400.0 Ω
2 Ω
± 5.0% ± 5 Ω
400.1 - 600.0 Ω
5 Ω
± 10% ± 10 Ω
600.1 - 1500 Ω
20 Ω
± 20%

1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered.

2 Resistance Measurement Frequency: 1.667KHz,3.333KHz(optional)

Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5)
Range
Resolution
Accuracy of Reading
0.200 - 1.000 mA
0.001 mA
± 2.0% ± 0.05 mA
1.00 - 10.00 mA
0.01 mA
± 2.0% ± 0.03 mA
10.0 - 100.0 mA
0.1 mA
± 2.0% ± 0.3 mA
100 - 1000 mA
1 mA
± 2.0% ± 3 mA
0.20 - 35.00 A(5637)
0.01A
± 2.0% ± 0.03A
0.20 - 15.00 A(5601)
0.01A
± 2.0% ± 0.03A
0.20 - 30.00 A(5601)
0.01A
± 3.0% ± 0.03A
General Specification
Accuracy of Resistance Calibration Plate ±0.5%
Data Logging Capacity 116 records
Data Logging Interval 1 to 255 seconds
Conductor Size 35mm /1.38”(5637), 23mm /0.90”(5600,5601)
Jaw Opening 38mm /1.49”(5637), 27mm /1.06”(5600,5601)
Battery Type 9V IEC 6 LR61 (Alkaline)
Display Type 4 digits 9999 counts LCD
Overload Indication OL
Battery Life 3000 measurements
Low Battery Indication  
Range Selection Auto
Power Consumption 40mA
Sampling Time 0.5 seconds
Operating Temperature 0 ℃ to 50 ℃ (14 ℉ to 122 ℉ ) Operating Humidity: Less than 85% RH
Storage Temperature -20 ℃ to 60 ℃ (-4 ℉ to 122 ℉ ) Storage Humidity: Less than 75% RH
Dimension( 5637 276mm (L) x 100mm(W) x 47mm(H),10.8" (L) x 3.9"(W) x 1.9"(H)
Dimension( 5600,5601 ) 257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H)
Weight( 5637) 750g/1.65lbs
Weight( 5600,5601) 640g/1.41lbs
Accessories
  • Resistance Calibration Plate x 1
  • Battery 9V (Installed) x 1
  • Carrying Box x 1
  • Users Manual x 1
TES-1360A Humidity/Temperature Meter

  • Laboratory
  • Quality Control
  • Air-Conditioning
  • Process Engineering
 
 
Range: Humidity 10% to 95% R.H.
Temperature -20 ℃ to +60 ℃ ; -4 o F to +140 ℉
Resolution 0.1% R.H. 0.1 ℃ , 0.1 ℉
Accuracy (after calibration)
Humidity +/ - 3% R.H. (at 25 ℃ , 30...95% R.H.)
Temperature +/ - 0.8 ℃ , +/ - 1.5 ℉
Response time
Humidity 45% R.H. --> 95% R.H. < = 3min
95% R.H. --> 45% R.H. < =5min
Temperature 1 ℃ /2 sec
Accessories Carrying case, Instruction manual, Battery.
Auxiliary outputs
Humidity 10mV DC/1% R.H.
Temperature 10mV DC/1 o C, 10mV DC/1 o F
Operating/Storage Condition
0 ℃ to 50 ℃< 80% R.H.
-10 ℃ to 60 ℃< 70% R.H.
Power Source 10mV DC/1 ℃ , 10mV DC/1 ℉
Size 270mm(L)x68mm(W)x25mm(H)
Weight 200g
Accessories Instruction Manual, Battery and Carrying Case
TES-1361 Datalogging Humidity/Temperature Meter

  • Instant preformance of Humidity measurement by precision thin-film capacity sensor
  • Dual display LCD / Clock
  • Compact, light weight & Simple operation
  • 7000 Record Data logging Capacity (Dual Reading)
  • RS-232 interface (software included)
 
Measurement Range
Humidity 10%… 95%R.H. Temperature -20 ℃ ..+ 60 ℃ 4 ℉ …+140 ℉
Resolution
0.1% R.H. 0.1 ℃ , 0.1 ℉
Accuracy
Humidity +/- 3%R.H. (at 25 ℃ , 30…95%R.H.)
Temperature +/- 0.8 ℃ , +/- 1.5 ℉
Sensor type
Humidity----------precision capacitance sensor
Temperature---semiconductor sensor
Response time
Humidity 45%R.H.--- 95%R.H. <= 3min
95%R.H.--- 45%R.H. <= 5min
Temperature 5 sec./10 ℃
Sampling rate
1 time per second
Record (Data logging)
7000 Point Data logger (Dual Data)
Operating temperature and humidity
0 ℃ to 40 ℃ , below 80% R.H.
Storage temperature and humidity
-10 ℃ to 60 ℃ , below 70% R.H.
Power supply
006P 9V or IEC6F22, NEDA 1604 battery
Battery life
Approx. 50hours (Alkaline)
Dimensions
270(L)×68(W)×25mm(H), 10.6"(L)×2.7"(W)×1"(H)
Weight
Approx. 200g, (7.1oz)
Accessories
Instruction manual, Battery, Carry case, Software,
RS-232 cable, 9 Pin to 25 Pin gender changer.
TES-1362 Printing Humidity Temperature Meter

  • Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ).
  • Dew Point Reading.
  • Max / Min / Data Hold.
  • Real Time Stamp.
  • Periodically Print out from Pre-Set time Interval.
 
Measuring Range T1 : Temperature : - 20 ℃ ~ 60 ℃ (- 4 ℉ ~ 140 ℉ )
Humidity : 10%RH ~ 95%RH
T2 : Type K : - 200 ~ 1333 ℃ (- 58 ~ 2431 ℉ )
Resolution 0.1 ℃ /0.1 ℉ /0.1%RH
Accuracy T1 : Temperature : +/- 0.8 ℃ , +/- 1.5 ℉
Humidity : +/- 3%RH (at 25 o C, 30….95%RH)
T2 : Type K : - 50 ℃ ~ 500 ℃ , +/- (0.1%rdg + 0.8 ℃ )
500 ℃ ~ 1333 ℃ , +/- (0.2%rdg + 1.8 ℃ )
Input Protection 60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector.
Sampling Rate 1 time/sec
Operating Conditions 0 ℃ ~ 40 ℃ (32 o F ~ 104 ℉ )
10 ~ 80% R.H.
Power Source 6 pcs size AAA Alkaline Battery or 9V DC adaptor/500mA minimum.
Battery Life Approx. 30 hours.
( interval printing = 60 minute, not including beeper).
70 hours ( except printing & beeper).
Size 193(L) x 74(W) x 37(H)mm
Weight Approx. 385g
Accessories 1. Carrying case, Instruction manual, Battery, type K probe (TP-K01).
2. Two rolls thermo-paper.
3. Humidity / Temperature Probe.

 

TES-1366 Humidity Temperature Meter

  • Dual LCD display.
  • Dew Point Reading.
  • Wet bulb Reading.
  • MAX/MIN with Time Stamp.
  • Data Hold function.
  • ℃ & ℉ Switchable.
  • Auto Power Off.
 
Measuring Range Temperature : -20℃ ~ 60℃ (-4℉ ~ 140℉)
Humidity : 1%RH ~ 99%RH
Resolution 0.1℃/0.1℉/0.1%RH
Accuracy Temperature : ±0.8℃, ±1.5℉
Humidity : ±3%RH
Sampling Rate 2 times/sec
Operating Conditions 0℃ ~ 60℃ (32℉ ~ 140℉) & 10 ~ 80% R.H.
Power Source 9V Battery
Battery Life Approx. 200 hours
Size & Weight 200mm(L) × 44mm(W) × 40mm(H) / 160g
Accessories Instruction manual, Battery, Carrying case.
TES-1336A Datalogging Light Meter (RS-232)

  • Spectrum of photo sensor meets C.I.E. photopic curve V( l )
  • 16000 Records Data logging capacity
  • RS-232 interface (software included)
  • Measurement of luminous intensity (PC Software)
 
Measuring range 20/200/2000/20000 Lux, 20/200/2000/20000 Fc
Luminous intensity (cd) ntensity = illuminance x (length) 2
Length feet (Fc)
meter (Lux)
Resolution 0.01 Lux
Accuracy ±( 3% rdg + 5dgts )
(calibrated to standard incandescentlamp, 2856 K)
Overrang display OL
Record (Data logging) 16000 Point Data logger
Sensor Silicon photo diode
Sensor lead length 150cm (approx)
Sensor probe 100(L) x 60(W) x 27(H) mm
Power source One 9V battery
Battery life 50hrs (approx)
Operating Storage Condition 0 o C ~ 40 o C ( 32 o F~104 o F ) below 80% RH
-10 o C ~ 60 o C ( 14 o F~140 o F ) below 70% RH
Dimensions 146(L) x 70(W) x 39(H) mm
Weight 300g (approx)
Accessories Carrying case、9V battery、instruction manual、Software、RS-232 cable、 9 Pin to 25 Pin gender
changer screwdriver.

 

TES-1339 Light Meter Pro.

  • Dual Display, 4-digit LCD reading.
  • Spectral Sensitivity close to CIE photopic Curve.
  • Measuring Levels Ranging 0.01 to 999900 Lux,0.01 to 99990 fc, Autoranging 5 step.
  • Accurate and Instant response.
  • Integral illuminance measurement.
  • Luminous intensity measurement.
  • Data Hold function.
  • Data memory and read function.
  • Reference value setting for relative or percentage deviation measurement.
  • Ripple measurement for STRAY + LIGHT function.
  • Time-hold function.
  • Point - average function.
  • Comparator function.
  • Auto power off function.
  • CNS 5119 Class Ⅱ .
 
Display Dual display 4 digit LCD read out.
Measuring Range 99.99, 999.9, 9999, 99990, 999900 Lux
9.999, 99.99, 999.9, 9999, 99990 fc
Auto rangeing (5 step) (1 fc = 10.76 Lux)
Overrange Display OL is displayed
Resolution 0.01 Lux, 0.001 fc
Accuracy ± 3% rdg ± 5dgt (Calibrated to standard
incandescent lamp, 2856° Κ )
CIE photopic f ' 1 ≦ 6 %
Temperature Characteristics

± 0.1%/ ℃

Measuring Rate Approximately 5 time/sec
Photosensor Silicon photodiodes
Data Memory Capacity 50 sets. (Direct reading from LCD display)
Operating / Storage Conditions 0 ℃ ~ 50 ℃ <80% RH
-10 ℃ ~ 60 ℃ <70%RH
Power Source 6 pcs AAA size Battery

Battery Life (typical)

100 hours
Photosensor Lead Length 150 cm (approx.)
Photosensor Dimensions 100(L) × 60(W) × 27(H)mm
Dimension 150(L) × 72(W) × 33(H)mm
Weight 250g
Accessories Carrying case, Instruction manual, Battery
AVM-01/03 Anemometer

  • Sensitive for low/high air velocity
  • Ergonomic Design
  • 0.3~45m/s range
 
 
Measurement
Range
Resolution

Accuracy

Air Velocity
M/S
0.3-45.0

0.1

+/- 3% or 0.1
KNOTS
0.6-88.0

0.1

+/- 3% or 0.1
ft/min
60-8800

10

+/- 3% or 10
Km/hr
1-140.0

0.1

+/- 3% or 0.1
Optional Range
MPH
0.7-100.0

0.1

+/- 3% or 0.1
Temperature AVM-03
0-60

0.1

+/- 0.8
Temperature AVM-03
32-140

0.1

+/- 1.5
Operating Temperature 10℃-50℃
Operating Pressure 500mB-2bar
Display Large 3 1/2 digit LCD
Power Source 1pc of 9V Battery
Dimension 168mm x 90mm x 31.3mm
Weight 500g
Accessory Carrying Case, 9V Battery, Instruction Manual

 

AVM-05/07 Flow Anemometer

  • Flow(CFM,CMM)
  • Instant, Ave, 2/3max Flow Measurement
  • Velocity m/s, ft/min, knots,Km/hr, mph
  • LCD Dual Display
  • ℃ / ℉
 
Range of Wind Velocity: Auto Range
Units
Range
Resolution
Threshold
Accuracy
m/s
0.0~45.0
0.1
0.3
+/-3%+/-0.1dgts
ft/min
0.0~8800
0.1/1
60
+/-3%+/-10dgts
knots
0.0~88.0
0.1
0.6
+/-3%+/-0.1dgts
km/hr-
0.0~140.0
0.1
1.0
+/-3%+/-0.1dgts
mph
0.0~100.0
0..1
0.7
+/-3%+/-0.1dgts
m/s : meter per second ft/min : feet per minute
knots : nautical miles per hour Km/hr : Kilometers per hour
mph : miles per hour
Range of Area (CMM) : 0.01~9999 m 2 Range of Wind Flow(CMM) : 0.01~9999 x 100
(CFM) : 0.01~9999 ft 2 (CFM) : 0.01~9999 x 100
Unit Conversion Table
Unit
Range
Resolution
Accuracy
0.0~45.0
0.2
+/-1.0 ℃
32.0~113.0
0.36
+/-1.8 ℃
General Specification
Battery Type 9V
Display 2 x 4 Digits Dual Display LCD
Bearing Sapphire jewel bearing
Temperature K-type thermocouple
Operating Temperature Meter: 0 ℃ ~ 50 ℃ ( 32 ℉ ~122 ℃ )
Vane: 0 ℃ ~ 60 ℃ ( 32 ℉ ~140 ℉ )
Operating Humidity Less than80% RH
Storage Temperature ﹣40 ℃ ~ 60 ℃ (﹣40 ℉ ~140 ℉ )
Power Consumption Approx 3mA
Dimension Meter: 3.46" x 6.61" x 1.03"(88 x 168 x 26.2mm)
Vane: 2.60" x 5.22" x 1.15"(66 x 132 x 29.2mm)
Weight 350g / 12.34oz. (Battery included)
Accessories Carrying case x 1
User manual x 1
9VBattery x 1

 

TES-1333/1333R Solar Power Meter

  • Wide spectral range.
  • Excellent long term stability.
  • Cosine corrected.
  • Automatic transmission measurements.
  • Select either power or transmission.
  • Solar energy power or transmission.
  • Current time setting function.
  • User calibration factor setting function.
  • End-mount light sensor.
  • Select either W/m2 or Btu / (ft2*h) units
  • Data Hold / MAX / AVG modes.
  • Data Memory and Read function. (99 sets.)
  • Auto Data memory and RS232 interface to PC. (TES-1333R)
  • Meteorology
  • agriculture
  • solar radiation measurement
  • solar power research
  • physics and optical laboratories
  • solar transmission measurement
  • identify high performancewindows
 
Display 3-1/2 digits.Max.indication1999
Range

2000W/m 2 、634Btu/(ft 2 * h)

Resolution 1W/m2、1Btu/(ft2*h)
Spectral response 400-1100nm
Accuracy

Typically within ± 10W/m2[ ±3 Btu / (ft2*h) ] or ±5% , whichever is greater in sunlight; Additional temperature induced error ±0.38W/m2 / ℃ [ ±0.12 Btu / (ft2*h)/ ℃] from 25℃

Angular accuracy Cosine corrected <5% for angles <60 °
Drift <±2% / per year
Calibration User recalibration available
Over-input Display shows" "
Sampling Time Approx. 0.4 second
Manu data memory and read 99 sets
Auto data memory 32000 sets (TES-1333R)
Battery 4pcs size AAA
Battery Life Approx. 100 hours
Operating temp and humidity 0 ℃ to 50 ℃below 80%RH
Storage temp and Humidity -10 ℃ to 60 ℃ below 70% RH
Weight Approx. 165g
Dimension 111(L)*64(W)*34(H)mm
Accessories Carrying Case, Operation Manual, 4 pcs size AAA, RS232 cable(for TES-1333R), CD saftware (For TES-1333R)

Home  |  Product Catalog  |  Buy Leads  |  Day & Night Color Cameras  |  Dual Core Infrared Cameras  |  Zoom Cameras  |  Vandal Proof/Dome Camera  |  High Speed Dome Camera  |  IP/Network Cameras  |  Wireless Cameras  |  Digital Video Recorder (1)  |  Digital Video Recorder (2)  |  Test & Measurement Instruments  |  Contact Us  |  Sitemap