Home
Product Catalog
Buy Leads
 Day & Night Color Cameras
Dual Core Infrared Cameras
Zoom Cameras
Vandal Proof/Dome Camera
High Speed Dome Camera
IP/Network Cameras
Wireless Cameras
Digital Video Recorder (1)
Digital Video Recorder (2)
Test & Measurement Instruments
Contact Us
Product Catalog 
 
Product Catalog > Digital Multimeter
PROVA-901/903 Digital Multi-Meter
PROVA-901/903 Digital Multi-Meter
Model No.︰PROVA-901/903
Brand Name︰PROVA
Country of Origin︰-
Unit Price︰USD $ 220 / pc
Minimum Order︰10 pc

 Total 22 Related Items 
Prev45678Next
Auto next page:   SecondsPlay

Product Description
PROVA-901/903 Digital Multi-Meter

The DMM to replace your bench-top one

  • 0.02% DC and 0.1% AC basic accuracy
  • 60,000 counts resolution
  • 200KHz (max.) bandwidth
  • True RMS with fast ACV/ACA response
  • Dual channels measurement similar to a dual channels DSO (V+V, V+A)
  • RS-232C ASCII interface
  • Data logging (model 903 with 10,708 records for both channels)
  • Capacitance measurement
  • Free software (901,903)
  • 1/3 the cost
 
The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.
Continuity : ( , open voltage 3V approx.)
Range Resolution Beeper Overload Protection
999.99 Ω 0.01 Ω < 40 Ω ( approx ) AC 1000V
Diode Test : (open voltage 3V approx.)
Range Resolution Short Circuit Current Overload Protection
3.0000V 0.0001V 0.8 mA typical AC 1000V
Frequency :
Range ( Auto ) Resolution Accuracy Overload Protection
1Hz - 200KHz( sine wave ) 0.0001Hz -100Hz ±0.02%±4dgts AC 1000V
1Hz -2MHz (TTL) 0.0001Hz - 0.0001MHz ±0.005%±4dgts AC 1000V
Duty Cycle : (%, TTL, 1Hz – 600KHz )
Range Resolution Accuracy Overload Protection
0.001% - 9.999% 0.001% ±30d/KHz±30dgts AC 1000V
10.00% - 100.00% 0.01% ±3d/KHz±3dgts AC 1000V
Resistance: ( Ω )
Range Resolution Accuracy Overload Protection
999.99 Ω 0.01 Ω ±0.15%±8dgts AC 1000V
9.9999K Ω 0.0001K Ω ±0.09%±3dgts AC 1000V
99.999K Ω 0.001K Ω

±0.09%±3dgts

AC 1000V
999.99K Ω 0.01K Ω ±0.09%±3dgts AC 1000V
9.9999M Ω 0.0001M Ω ±0.2%±6dgts AC 1000V
40.000M Ω

0.001M Ω

±1%±6dgts AC 1000V
Capacitance: ( , auto range , and for film capacitor or better)
Range Resolution Accuracy 1
60.00nF 0.01nF ±0.8%±5dgts
600.0nF 0.1n F ±1.5%±5dgts
6.000 μ F 0.001 μ F ±1.5 %±5dgts
60.00 μ F 0.01 μ F ±2.0%±5dgts
600.0 μ F 0.1 μ F ±3.5%±5dgts
DC Voltage: (Input Impedance: 10M )
Range

Resolution

Accuracy Overload Protection
60.000mV 0.001mV ±0.1%±5dgts 1 DC 1000V
600.00mV 0.01mV ±0.02%±3dgts DC 1000V
6.0000V 0.0001V ±0.02%±3dgts DC 1000V
60.000V

0.001V

±0.02%±3dgts DC 1000V
600.00V 0.01V ±0.02%±3dgts DC 1000V
1000.0V 0.1V ±0.04%±3dgts DC 1000V

DC Current: (10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )

Range

Resolution

Accuracy

600.00 μ A

0.01 μ A ±0.2%±10dgts
6000.0 μ A

0.1 μ A

±0.1%±10dgts
60.000mA 0.001mA ±0.2%±10dgts
600.00mA 0.01mA

±0.1%±10dgts

1.0000A 0.0001A ±0.1%±10dgts
10.000A 1 0.001A ±0.3%±10dgts

AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 20KHz, True RMS, 10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )

Range (ACA) Resolution Accuracy (50/60Hz) Accuracy (45Hz - 1KHz)
600.00 μ A 0.01m A ±0.3%±20dgts ±0.4%±20dgts
6000.0 μ A 0.1m A ±0.3%±20dgts ±0.4%±20dgts
60.000mA 0.001mA ±0.3%±20dgts ±0.4%±20dgts
600.00mA 0.01mA ±0.3%±20dgts ±0.4%±20dgts
1.0000A 0.0001A ±0.3%±20dgts ±0.4%±20dgts
10.000A 1 0.001A

±0.5%±20dgts

±0.4%±20dgts
 

Range

(ACA)

Accuracy

(20Hz - 45Hz)

Accuracy

(1KHz – 10KHz)

Accuracy

(10KHz – 20KHz)

600.00 μ A ±1%±20dgts ±2%±20dgts ±1%±20dgts
6000.0 μ A ±1%±20dgts ±2%±20dgts ±1%±20dgts
60.000mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts
600.00mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts
1.0000A ±1%±20dgts ±1.5%±20dgts Not Specified
10.000A 1 ±2%±20dgts ±1.5%±20dgts Not Specified
AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz – 10KHz, average sensing. Input Impedance is 10M , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the unit.

Range

(ACV)

Resolution

Accuracy

(50/60Hz)

Accuracy

(45Hz - 1KHz)

Accuracy

(20Hz - 45Hz)

60.000mV 0.001mV ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts
600.00mV 0.01mV ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts
6.0000V 0.0001V ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts
60.000V 0.001V ±0.1%±20dgts

±0.3%±20dgts

±0.8%±25dgts
600.00V 0.01V ±0.1%±20dgts ±0.5%±20dgts ±0.8%±25dgts

1000.0V

(0–400V)

0.1V

±0.1%±20dgts

±2%±30dgts

±0.8%±25dgts

1000.0V

(400-1000V)

0.1V

±0.1%±20dgts

(45Hz – 400Hz)

±2%±30dgts

±0.8%±25dgts
 

Range

(ACV)

Accuracy

1KHz–10KHz)

Accuracy

(10KHz–20KHz)

Accuracy

(20KHz-50KHz)

Accuracy

(50KHz-100KHz)

Accuracy

(100kHz-200KHz)

60.000mV ±2%±20dgts ±2.5%±20dgts ±4%±40dgts ±4%±40dgts Not Specified
600.00mV ±1%±20dgts ±2.5%±20dgts ±2%±40dgts ±2%±40dgts ±2%±40dgts
6.0000V ±1%±20dgts ±2.0%±20dgts ±2%±40dgts ±2%±40dgts ±2%±40dgts
60.000V ±1%±20dgts ±2.0%±20dgts ±4%±40dgts Not Specified Not Specified

600.00V

(0-400V)

±5%±20dgts Not Specified Not Specified Not Specified Not Specified

600.00V

(400-600V)

Not Specified Not Specified Not Specified Not Specified Not Specified

1000.0V

(0-400V)

±2%±40dgts Not Specified Not Specified Not Specified Not Specified

1000.0V

(400-1000V)
Not Specified Not Specified Not Specified Not Specified Not Specified
Supplemental Dual Channels Specification (DC – 400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
ACV (Ch2) DCV (Ch2) ACA (Ch2) DCA (Ch2)
ACV (Ch1)

±1%±( V1 - V2 ) 200 PPM (Ch1, Ch2)

±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2)
±0.1 μ A / V( μ A,Ch2)
±1 μ A / V (mA,Ch2)
±0.2mA / V (A, Ch2)
±2mV / A (mV, Ch1)
± 5mV / A (V, Ch1)
±0.25% (Ch1, Ch2)
DCV (Ch1) ±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2) ±0.25% (Ch1,Ch2 ±0.25% (Ch1, Ch2) ±0.25% (Ch1, Ch2)
General Specification
Battery Type 9V
Display 5 + 5 digits LCD with 30 segments bar graph
Range Selection auto and manual
Overload Indication OL
Power Consumption 6 mA ( approx )
Low battery Indication
Operating Temperature -10 C to 50 C
Operating Humidity

less than 85% relative

Altitude up to 2000M
Storage Temperature -20 C to 60 C
Storage Humidity less than 75% relative
Dimension 207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H)
Weight 430g / 15.2oz (battery included)
Accessories
Users manual x 1
9V battery x 1
RS-232C interface cable
Product Image
PROVA-901/903 Digital Multi-Meter
Related Products
Luminous Flux Meter/Light Meter
Luminous Flux Meter/Light Meter
USD $ 450
ST512,T510,ST513 UltraViolet Meters
ST512,T510,ST513 UltraViolet Meters
USD $ 350
UT531 Insulation Resistance Testers
UT531 Insulation Resistance Testers
USD $ 88
UT81A  Scope Digital Multimeters
UT81A Scope Digital Multimeters
USD $ 88

Home  |  Product Catalog  |  Buy Leads  |  Day & Night Color Cameras  |  Dual Core Infrared Cameras  |  Zoom Cameras  |  Vandal Proof/Dome Camera  |  High Speed Dome Camera  |  IP/Network Cameras  |  Wireless Cameras  |  Digital Video Recorder (1)  |  Digital Video Recorder (2)  |  Test & Measurement Instruments  |  Contact Us  |  Sitemap
  English     简体版     繁體版
Powered by DIYTrade.com
HomeContact UsSitemap