8921 & 8922 AT A GLANCE
DIGITAL DISPLAY WITH ANALOG GRAPH! BACKGROUND NOISE ABSORBER ! MAX / MIN RECORD, MAX HOLD ! RS232 INTERFACE ! MEETS IEC 651, TYPE 2 CLASS !
FEATURE
|
|
Meets IEC 651;ANSI S1.4, type2 standard. |
|
|
Quasi-Analog bar indicator:1dB display steps, 50dB display range, updated every 50ms. |
|
|
Measurement level range features 6 ranges. |
|
|
Background noise absorber mode filters ambient sounds. |
|
|
Fast( 125 msec.) or Slow( 1 sec.) respone 3 times. |
|
|
Record Max / Min. & Maximum Hold function. |
|
A / C Weighting selectionable. |
|
|
Microphone : 6mm(Dia.)electric condenser type. |
|
Backlight for use in dark areas (Model 8922). |
|
Low battery indicator. |
|
Optional RS232 software (Disk & PC cable). |
|
Serial formt: 2400Baud rate, 1 Stop bit, 8 Data bits. N: xxx, xdB |
|
Monitor the sound levels from traffic noise, alarm systems and workplace machinery, |
|
Multi-Freguency calibration to ensure quality stable. |
|
|
|
| SPECIFICATION |
|
Auto range : |
30-130dB. |
|
Big LCD : |
42x64mm. |
|
Measurement level range :
| |
6 ranges in 10-dB steps:30-80dB, 40-90dB, 50-100dB, 60-110dB, 70-120dB, 80-130dB. |
|
|
Accuracy : |
±1.5dB ( under reference condition ) |
|
Digital display : |
3-1/2 dight LCD, 0.1dB resolution updated 0.5seconds. |
|
Analog output : |
AC:0.707vrms( at full scale )
DC:10mV/ dB |
|
Measurement frequency range : 31.5Hz-8KHz. |
|
|
Measurement level A weighting : |
30dB~130dB. |
|
Measurement level C weighting : |
35dB~130dB. |
|
Operation temperature : |
0~50℃,10~90%RH |
|
Storage temperature : |
-20~60℃ |
|
Meter includes hard ABS case, battery, manual. |
|
Battery life : |
20 hours typical (9V) |
|
Dimensions (meter WxHxT) : |
80 x 256 x 38mm |
|
|
|
|
|
|